Long distances or transport times? No power or oxygen supply? With a ventilator that maintains ventilation for 7.5 hours*, even without an external supply of compressed gas, you don’t need to worry about the technology. MEDUVENT Standard is one of the smallest turbine-driven ventilators in the world and makes you independent of oxygen cylinders. If required, however, you can still administer additional oxygen to the person undergoing treatment at any time via the universally compatible oxygen inlet tube. This allows inspiratory oxygen concentrations of 21 % to 100 % to be achieved.
In emergency response, the speed at which you initiate therapy on that person is often of key importance for the success of their therapy. MEDUVENT Standard enables you to ventilate ergonomically in a controlled and efficient manner – without having to set ventilation parameters by a complicated process. As a result, the patient is taken care of as quickly as possible, safely, and in accordance with guidelines.
Every move has to be perfect when respiration support is involved – the pressure on emergency medical services in these situations is high. In such cases, a ventilator that is easy to operate has a great impact on the success of therapy. MEDUVENT Standard opens up completely new prospects in modern emergency and transport ventilation.
Numerous features ensure that the intuitively-operated emergency ventilator offers maximum safety in use. Users can select different modes and options for invasive and non-invasive ventilation, which increases patient safety compared to bag mask ventilation. MEDUVENT Standard is your reliable partner during an emergency response – for the ground emergency medical services, the air rescue service, or in the military medical corps.
* assuming typical ventilation settings for an adult patient
If you want to supply your patients with 100 % oxygen and then adapt the dose, simply connect the inhalation outlet of the pressure reducer to the oxygen inlet of MEDUVENT Standard using the globally-compatible oxygen inlet tube. You can then set the desired flow.
As MEDUVENT Standard runs purely on electricity, and not on compressed gas, the device does not use any oxygen to run. If you do not have any medical oxygen available but still want to ventilate with more than 21 % oxygen, you can use concentrator oxygen. To do this, just change the operating gas and connect the concentrator or the oxygen cylinder to MEDUVENT Standard.
It goes without saying that you can also operate MEDUVENT Standard with ambient air, without any oxygen source at all. The hygiene filter cleans the air used, removing viruses, bacteria, and particles, thus protecting both people and the device from contamination. You can select the CBRN (chemical, biological, radiological, and nuclear hazards) option to perform ventilation in unconventional situations.
MGM Associates #209, Ansal Majestic Tower, Vikaspuri, New Delhi -110018
© copyright 2026 MGM Associates | Web Development By Magicworks
MGM Associates #209, Ansal Majestic Tower, Vikaspuri, New Delhi -110018
© copyright 2026 MGM Associates | Web Development By Magicworks
Fill out the form
Fill out the form, to get more detail information regarding products.